Applications
M2500 Fire + Smoke Curtain
M2500

M2500 Fire + Smoke Curtain

Flexibility is the defining characteristic of this fire + smoke curtain. Available in large dimensions, this vertically deploying solution is suitable for atrium separation, openings in walls, and specialty enclosures where fire-rated protection is required. This specialized curtain assembly can be also be specified with manual egress (see M2500E).

M2500

Product Details

Product Models

ModelDescription
M2500The standard vertically deploying fire + smoke curtain: a fire and smoke rated fabric curtain in a steel housing that protects openings as part of a smoke control system. 2-hour fire endurance rated (UL 10D) and rated for smoke and draft control (UL 1784, NFPA 105).
M2500E (Egress)The M2500 with manual egress. A split curtain provides egress access per ICC AC77, and wall-mounted door activation switches retract the deployed curtain to allow passage before it automatically redeploys.
M2500 DraftThe draft curtain configuration of the M2500, used for smoke and draft control applications where a fire endurance rating is not required.

System Rating

The M2500 system is 2 hour (120 minute) Fire Endurance Rated system complying with the UL 10D standard and listed by Intertek Laboratories. The M2500 | Fire + Smoke system is also rated to UL 1784 and listed by Intertek Laboratories according to the requirements of smoke and draft control assemblies defined in NFPA 105.

Clear Opening Sizes

For openings:

  • ≤ 60′ wide x ≤ 12′ tall
  • ≤ 50′ wide x ≤ 16′ tall
  • ≤ 40′ wide x ≤ 20′ tall

Housing Dimensions

  • For systems with drop lengths less than or equal to 12′: 10″ high by 9″ deep
  • For systems with drop lengths of greater than 12′: 11.75″ high by 10.5″ deep

Unit Electrical Control

System controls are listed in accordance with UL 864 for releasing devices. External control box mounted outside of the unit, may be mounted up to 30 conduit feet away. Optional Firefighters Smoke Control Station (FSCS) panel connectivity available when configuring.

Emergency Power Source

Each unit has a battery that can power the unit for up to 18 hours on loss of primary power. Emergency power source will take over automatically if primary AC power is disrupted.

Product Options

Option Description
Curtain Switch Key-operated deploy/retract switch, mountable on opposing walls, used to cycle the curtain for inspection and testing.
Firefighters Smoke Control Station (FSCS) Full interface to the fire service interface system, giving fire service personnel dedicated monitoring and control of the curtain as part of the building smoke control system.
SGTex-10 / SGTex-30 Fabrics Optional curtain fabric upgrades for applications with additional performance requirements. Contact Smoke Guard for details.
Wall Mount / Manual Egress Switches Wall-mounted door activation switches on either side of the opening that retract the deployed curtain for passage, then automatically redeploy it (M2500 Egress).
Mandatory Testing Key Switch Key switch used to perform the required periodic deployment testing of the system.
Building Emergency Power Tie-In Connection to building standby power to supplement the integrated 24 VDC battery back-up (up to 18 hours of protection on loss of primary power).

Downloads / Links

DocumentM2500M2500E (Egress)M2500 Draft
Design DetailsDWG PDFPDF DWGPDF DWG
Technical Data SheetPDFPDF
Controller Technical Data SheetPDFAll models
Electrical DiagramPDF
Revit/CAD DownloadsLINKAll models
California State Fire Marshal (CSFM) ListingPDF
Spec Center - Download SpecsLINKAll models
Intertek ListingLINKLINK
Product Overview DrawingsLINKAll models
Service & RepairsLINKAll models

Related Videos

Want to see more? Visit the Smoke Guard YouTube channel for more product and installation videos.

Frequently Asked Questions

What is the difference between the M2500, M2500E, and M2500 Draft?

All three are vertically deploying Smoke Guard curtains built on the same platform. The M2500 is the standard fire + smoke rated curtain, with 2-hour fire endurance (UL 10D) and smoke and draft control ratings (UL 1784, NFPA 105). The M2500E adds manual egress: a split curtain per ICC AC77 and wall-mounted switches that retract the deployed curtain for passage before it automatically redeploys. The M2500 Draft is the draft curtain configuration, used for smoke and draft control where a fire endurance rating is not required.

What fire and smoke ratings does the M2500 carry?

The M2500 is a 2-hour (120 minute) fire endurance rated assembly complying with UL 10D and listed by Intertek Laboratories. It is also rated to UL 1784 for air leakage and meets the requirements for smoke and draft control assemblies defined in NFPA 105. System controls are listed in accordance with UL 864 for releasing devices.

What is the largest opening the M2500 can protect?

The M2500 protects openings up to 60′ wide by 12′ tall, 50′ wide by 16′ tall, or 40′ wide by 20′ tall. Contact Smoke Guard for additional sizing options.

How does the M2500 deploy during a fire event?

The system deploys on a signal from the local smoke detection system or a smoke control panel. It is a gravity fail-safe design, and each unit includes a battery back-up that can power the unit for up to 18 hours if primary power is lost, taking over automatically.

Can occupants exit through the curtain after it deploys?

Yes, with the M2500E egress model. Its split curtain provides manual egress access per ICC AC77, and door activation switches mounted on opposing sides of the opening retract the curtain to allow passage. The curtain automatically redeploys after a brief pause while the alarm remains active.

What maintenance and testing does the M2500 require?

Every system includes a mandatory testing key switch for the required periodic deployment tests, and Smoke Guard systems are installed and serviced by factory recognized personnel. Visit our Service & Repairs page to schedule service or learn more.

Have a Question or Need Assistance?

Our team is ready to help with product selection, design, and specifications. Reach out and a Smoke Guard expert will get back to you.